Solar-Log1000: Configuration at the unit
Configuring the connection to the large display (Extended/Large display)
242 of 268 Solar-Log
1000/500/200
Installation
Dialogue boxes
RS485-A, RS485-B, S0 output
These check boxes are used to activate the display on the corresponding
interfaces and appear in the various dialogue boxes that appear one after
the other in the dialogue sequence.
On the right of the checkbox is a display field which indicates if and how
the interface is already assigned.
Schneider Displaytechnik, RiCo Electronic Design, HvG Hard &
Software Engineering
These 3 large displays are currently supported on the RS485/422 B and
RS485 A interfaces.
System group
Here you can select which system group is to be shown on the large dis-
play. If no groups are used, the whole system is shown.
Procedure
1 Enable the checkbox for the interface connection and the radio button for
the connected display
2 Touch the button beside System group
A selection list is displayed.
3 Select the system group to be shown on the large display and touch Back
to continue
4 Touch Save, then if necessary touch Next to go to the next dialogue if you
want to configure other displays.

Note
If the display is being configured on the S0 output, a pulse factor has to be
entered ( Page 137):
The pulse factor in Solar-Log
1000
must be the same as the pulse factor on the
large display.