Connecting the inverters
Pairan
122 of 268 Solar-Log
1000/500/200
Installation
4.60 Pairan
Overview
Interface integrated
Where to connect: Round socket on inverter
2 pin wiring
Communication address must be allocated.
Work steps
• Switch off the inverters and SolarLog™; (Page 16).
• Connect inverters to the Solar-Log™
• Connect the inverters to each other
Connect inverters to the Solar-Log™
The wiring is done using the
self-made cable connection with the round plug and the terminal strip plug
(Page 15).
The round plug must be obtained from the manufacturer.
Procedure
1. If your have made the cable yourself, connect the wires as shown in
the following diagram:
Connection socket view
Solar-Log™ terminal block connector
2. Insert the terminal block connector into the SolarLog™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 2 wire, shielded data cable.
Where to connect: Round socket on inverter