Configuration at a PC
Setting automatic/manual data backups (Internal/Backup)
188 of 268 Solar-Log
1000/500/200
Installation
Data correction section
Here you can adjust the values for previous days or change daily totals.
1 Enter the Date (on 8 digits): 2 digits for day, 2 digits for month and
2 digits for the year, separating each by a decimal point
2 Enter the Daily value in kWh
The daily value must correspond to the current meter reading, i.e. the real
daily value.
Data import section
An initial value can also be input to daily data already saved manually in So-
lar-Log. This is useful any time that a large amount of data has to be saved
at a later time, and this would take too long with the Data correction function.
Data import deletes the existing data memory completely before the daily data
are imported. Therefore, the data import should be carried out as far as possi-
ble immediately after the startup of Solar-Log™.
A data import can only be made if all inverters have been correctly detected
and configured.
1 Before data import, Solar-Log™ asks for a user name and password. Enter
the following details:
User name: solarlog
Password: solarlog
2 Click on Browse...
A box opens in which you can select the import file.
3 Click on Load
The data are loaded.
The import file must consist of individual rows of text, where the date and daily
yield value in Wh (not kWh!) are separated by semicolons (CSV format).
Example:
01.04.06;136435
02.04.06;128219
etc.
Note: Here, the year value should also consist of 4 digits.