Configuration at a PC
Solar-Log1000, 500, 200: Configuring inverter data (Basic/Inverter)
Solar-Log
1000/500/200
Installation 165 of 268
Power meter at S0 input section (Solar-Log
200
00
/500/1000
)
This section is available only if a current meter is connected to a Solar-Log
500/1000
and is selected. The Monitoring section does not apply to the current meter.
The external current meter can be configured and used in 3 modes in Solar-
Log
1000
as the current meter for:
Inverter
The entire system or as
A consumption meter.
Enable the required option.
Monitoring section
This section is only available on the Solar-Log
20
200/500/1000 if the power me-
ter on the S0 input is activated in inverter mode.
Activated/Deactivated
Monitoring can be enabled or disabled for a desired period.
Message as e-mail /SMS
Malfunctions can be reported by e-mail and SMS messages.
The following are also monitored and detected:
Failure of an inverter
Loss of power in one of the module fields
Combined conditions for fault definition:
(Fields Monitoring period, Feed-in power, Deviation, Period of mal-
function)
Monitoring is based on a comparison of the power at all inverters, including
individual trackers in the case of inverters with more than one tracker. If the
target power deviates from the actual power by more than a certain toler-
ance (= min. feed-in power), a message can be sent by e-mail and/or SMS
after the selected fault duration is reached.