5.1.13 16-** Data Readouts
Par.
No. #
Parameter description Default value 2-set-up Change
during
operation
Conver-
sion index
Type
16-0* General Status
16-00 Control Word 0 N/A 1 set-up TRUE 0 uint_16
16-01 Reference [Unit] 0.0 ReferenceFeedbackUnit 1 set-up TRUE -3 Int32
16-02 Reference [%] 0.0 % 1 set-up TRUE -1 Int16
16-03 Status Word 0 N/A 1 set-up TRUE 0 uint_16
16-05 Main Actual Value [%] 0.0 % 1 set-up TRUE -2 Int16
16-09 Custom Readout 0.0 CustomReadoutUnit 1 set-up TRUE -2 Int32
16-1* Motor Status
16-10 Power [kW] 0.00 kW 1 set-up TRUE -3 Uint32
16-11 Power [hp] 0.00 hp 1 set-up TRUE -3 Uint32
16-12 Motor Voltage 0.0 V 1 set-up TRUE -1 Uint32
16-13 Frequency 0.0 Hz 1 set-up TRUE -1 Uint32
16-14 Motor Current 0.00 A 1 set-up TRUE -2 Uint16
16-15 Frequency [%] 0.0 % 1 set-up TRUE -1 uint_16
16-18 Motor Thermal 0.0 % 1 set-up TRUE 0 uint_8
16-3* Drive Status
16-30 DC Link Voltage 0 V 1 set-up TRUE 0 Uint32
16-34 Heatsink Temp. 0 °C 1 set-up TRUE 100 uint_8
16-35 Inverter Thermal 0.0 % 1 set-up TRUE 0 uint_8
16-36 Inv. Nom. Current 0.0 A 1 set-up TRUE -2 uint_16
16-37 Inv. Max. Current 0.0 A 1 set-up TRUE -2 uint_16
16-38 SL Controller State 0 N/A 1 set-up TRUE 0 uint_8
16-5* Ref. & Feedb.
16-50 External Reference 0.0 % 1 set-up TRUE -1 Int16
16-52 Feedback[Unit] 0.0 ProcessCtrlUnit 1 set-up TRUE -3 Int32
16-6* Inputs & Outputs
16-60 Digital input 0 N/A 1 set-up TRUE 0 Uint16
16-61 Terminal 53 Setting [0] Current mode 1 set-up TRUE - Uint8
16-62 Analog Input AI53 1.000 N/A 1 set-up TRUE -2 Uint16
16-63 Terminal 54 Setting [0] Current mode 1 set-up TRUE - Uint8
16-64 Analog Input AI54 1.000 N/A 1 set-up TRUE -2 Uint16
16-65 Analog Output AO42 [mA] 0.000 mA 1 set-up TRUE -2 Uint16
16-66 Digital Output 0 N/A 1 set-up TRUE 0
VisStr[4
]
16-71 Relay Output [bin] 0 N/A 1 set-up TRUE 0 Uint16
16-72 Counter A 0.0 N/A 1 set-up TRUE 0 Int16
16-73 Counter B 0.0 N/A 1 set-up TRUE 0 Int16
16-79 Analog Output AO45 0.000 mA 1 set-up TRUE -2 Uint16
16-8* Fieldbus & FC Port
16-86 FC Port REF 1 0 N/A 1 set-up TRUE 0 Int16
16-9* Diagnosis Readouts
16-90 Alarm Word 0.0 N/A 1 set-up TRUE 0 uint_32
16-91 Alarm Word 2 0.0 N/A 1 set-up TRUE 0 uint_32
16-92 Warning Word 0.0 N/A 1 set-up TRUE 0 uint_32
16-93 Warning Word 2 0.0 N/A 1 set-up TRUE 0 uint_32
16-94 Ext. Status Word 0.0 N/A 1 set-up TRUE 0 uint_32
16-95 Ext. Status Word 2 0.0 N/A 1 set-up TRUE 0 uint_32
Parameter Lists VLT HVAC Basic Drive Programming Guide