The thermostat has buttons for adjusting the temperature
setting, and a LED indicator showing standby periods
(green light) and heating periods (red light).
More information on this product can also be found at:
ectemp.danfoss.com
1.1 Technical Specifications
Operation voltage 220-240V~, 50Hz
Standby power con-
sumption
Max 0.30W
Relay:
Resistive load
Inductive load
Max 15A / 3450W @ 230V
cos φ= 0.3 max 1A
Sensing units NTC 15kOhm at 25°C
Sensing values:
0°C
25°C
50°C
42kOhm
15kOhm
6kOhm
Hysteresis ± 0.2°C with room sensor
± 0.4°C with floor sensor only
Ambient temperature -10°C to +30°C
Frost protection temp. 5°C -