Danfoss VLT 5000 FLUX Manual de Serviço

Consulte online ou descarregue Manual de Serviço para não Danfoss VLT 5000 FLUX. Danfoss VLT 5000 FLUX Technical data Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 34
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
MG.10.Q1.5B – VLT is a registered Danfoss trade mark
VLT 5000/5000 FLUX SyncPos Quick-Setup
Contents
Chapter 1
Safety ...................................................................... 2
Chapter 2
Introduction ........................................................... 3
Chapter 3
Typical application example.................................. 4
Chapter 4
Basic SyncPos information .................................. 6
Chapter 5
Installing the SyncPos PC Software ................... 8
Chapter 6
Checking encoder connections ........................... 9
Chapter 7
Commissioning Guide ........................................ 11
Chapter 8
10 steps to optimise the PID loop .................... 11
Chapter 9
Error and Messages ............................................ 17
Chapter 10
Technical data/wiring examples ........................ 25
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - Contents

1MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupContentsChapter 1 Safety ...

Página 2 - Warning:

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark10drive forward for example in local mode (Parameter002 = ”L

Página 3 - Introduction

11MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-Setup Commissioning GuidelineWhen the APOS user program is

Página 4 - Typical application example

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark12AV is the actual velocityAP is the actual position (calcul

Página 5

13MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupThis feature is also very helpful in applications wherethe

Página 6 - Basic SyncPos information

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark14 Optimizing your controller settings step-by-stepFor

Página 7

15MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupVmax: Is the maximum encoder velocity. Theunit is RPM. If

Página 8

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark16... the tolerated position error is exceededIf the test ru

Página 9

17MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupError messages VLT and SyncPos Motion Controller mes

Página 10 - Checking encoder connections

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark18Error messages SyncPos option messages in detailAs in

Página 11

19MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupO.ERR_11SyncPosAxis no. 1 Software limit switch activatedC

Página 12

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark2The voltage of the frequency converteris dangerous whenever

Página 13

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark20O.ERR_18SyncPosReset by CPUMeaningThe processor has been s

Página 14

21MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupO.ERR_70SyncPosError in DIM commandMeaningThe definition o

Página 15

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark22O.ERR_91SyncPosCurve array wrongMeaningAn incorrect or old

Página 16

23MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-Setup Error in array ...SyncPosError in array part of file.Mea

Página 17 - Error messages

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark24There are two interfaces to the SyncPos option:••••• 36 te

Página 18 - Error messages

25MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupDigital inputsMK3A is a 10pole terminal block with 8 digit

Página 19

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark26 Technical dataTerminals:Type ...

Página 20

27MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupEncoder input 2, MK3D (slave):Terminal designations ...

Página 21

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark28 Encoder monitorBoth encoder interfaces are equi

Página 22

29MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupSW 1.1: Connect(ON)/disconnect(OFF) 24 V from control card

Página 23

3MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-Setup About this manual: How is it arranged?Please read the

Página 24

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark30The terminating resistors on both end of thebus have to be

Página 25

31MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-Setupleft: encoder connection for positioning applicationsbelow

Página 26

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark32Encoder connections for the synchronizing withvirtual mast

Página 27 - ABSOLUTE ENCODER

33MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-Setup IndexAAbout this manual ...

Página 28

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark34OO.ERR_3 ... xx ...

Página 29

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark4 Description in briefThe tire will enter the conveyor

Página 30

5MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupTypical application example

Página 31

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark6 How SyncPos functionsLet us explain the basic princip

Página 32

7MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupBasic SyncPos information RequirementsSyncPos is for u

Página 33

VLT 5000/5000 FLUX SyncPos Quick-SetupMG.10.Q1.5B – VLT is a registered Danfoss trade mark8.This section offers you a quick general introductionwhich

Página 34

9MG.10.Q1.5B – VLT is a registered Danfoss trade markVLT 5000/5000 FLUX SyncPos Quick-SetupFunction of inputs and output must be selected inparameter

Comentários a estes Manuais

Sem comentários