SET 3E
Electronic 24 Hour Programmer
for Heating and Hot Water
Installation Guide
Danfoss Heating
MAKING MODERN LIVING POSSIBLE
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Installation Guide

SET 3EElectronic 24 Hour Programmerfor Heating and Hot WaterInstallation GuideDanfoss HeatingMAKING MODERN LIVING POSSIBLE

Página 2 - Certification Mark

SET3E10GB3.5 Typical Fully Pumped System with 3-Port Mid-Position ValveN L 1 2 3 4 5 63 amp fuse D.H.W. HTGON OFFMains SupplyNLProgrammer TerminalsN

Página 3 - Installation Instructions

Danfoss Heating11GB3.6 Typical Fully Pumped System with Spring Return Zone Valve in each ServiceOther Danfoss Randall products suitable for use wi

Página 4 - 1.0 Installation Guide

SET3E12GB3.7 Typical Fully Pumped System with Fully Motorised Zone Valve in each ServiceN L 1 2 3 4 5 63 amp fuse D.H.W. HTGONOFFMains SupplyNLPro

Página 5

Danfoss Heating13GBPlease see overleaf for a table containing replacement wiring information. Some timecontrols are connected in diff erent ways depend

Página 6 - 3.1 Wiring

SET3E14GBDANFOSS RANDALLSET3E(PUMPED)MAINS WATER HEATINGNOTE This conversion applies only if..An additional terminal block is required where these dis

Página 7 - DHW = Domestic Hot Water

Danfoss Heating15GBPOTTERTON MINI-MINDER N L 3 - 1 4 - 2Pumped/Gravity link is set to pumpedPOTTERTON EP2000, EP3000 N L 3 - 1 4 5 2Pumped/Gravity lin

Página 8 - AT cylinder thermostat;

Part No. 8633v01s6-1 03/11Danfoss Randall Ltd.Ampthill RoadBedford MK42 9ERTel: 0845 1217 400Fax: 0845 1217 515Email: [email protected]

Página 9

SET3E2For a large print version of these instructions please call Marketing on 0845 121 7400.Danfoss can accept no responsibility for possible errors

Página 10 - Mid-Position Valve

Danfoss Heating3GBInstallation InstructionsSET3EElectronic 24-Hour Programmer for Heating and Hot WaterIndex1.0 Installation Guide ...

Página 11 - AT cylinder thermostat

SET3E4GBSpecifi cationPower supply 230 ± 15% Vac, 50/60HzSwitch action 2 x SPDT Type 1B Switch ratingMax 264Vac, 50/60Hz, 3(1) ATiming accuracy ± 1 mi

Página 12

Danfoss Heating5GB5. Referring to the wiring diagrams on page 6-12, connect the unit as shown.6. The unit is supplied ready for use in systems havin

Página 13 - 4.0 Replacement

SET3E6GBNOTE: For mains voltage applications links must be fi tted between terminals L, 2 and 5. 3.1 WiringN/OONNOTES:FOR SET2E LINKTERMINALS 1 & 5

Página 14

Danfoss Heating7GBDHW = Domestic Hot Water3.2 Typical Gravity DHW Pumped HTGN L 1 2 3 4 5 63 amp fuse D.H.W. HTGON OFFMains SupplyNLProgrammer Termin

Página 15 - Danfoss Heating

SET3E8GB3.3 Typical Fully Pumped System with Spring Return Zone Valve in HeatingN L 1 2 3 4 5 63 amp fuse D.H.W. HTGON OFFMains SupplyNLProgrammer

Página 16 - Danfoss Randall Ltd

Danfoss Heating9GB3.4 Typical Gravity DHW Pumped HTG with Spring Return Zone Valve in DHWOther Danfoss Randall products suitable for use with ab