VLT
®
6000 HVAC
1
MG.60.G2.02 - VLT is a registered Danfoss Trademark
Contents
Introduction
Safety.......................................................................3
Safety Guidelines........................................................3
Warnings Against Unintended Start ...............................3
Introduction ...............................................................4
About this manual.......................................................4
Assumptions..............................................................4
References................................................................4
Trademarks ...............................................................5
Programming the VLT 6000
Control Panel.............................................................5
Parameter Change Keys .............................................5
Local Control .............................................................6
Quick Menu ..............................................................6
To Enter or Change Quick Menu Parameter Data...........7
Example of Changing Parameter Data...........................7
Extended Menu..........................................................8
HP/kW......................................................................8
VLT 6000 Functional Features
Drive Operation..........................................................8
Motor and Drive Thermal Protection .............................8
Set-up 1-4.................................................................8
Current Monitoring and Limits.......................................9
Direction of Rotation ...................................................9
Start/Stop..................................................................9
Freeze Mode .............................................................9
Coast........................................................................9
Motor Ramp-up and Ramp-down Rate .........................9
Lock Panel................................................................9
Hand/Auto Modes.......................................................9
Run Enable................................................................9
Bus Functions............................................................9
Frequency Out High, Low Limits...................................9
Relay Out 1,2 ...........................................................9
PID Control Functions................................................10
Sleep Mode .............................................................10
Drive Control Display .................................................10
Terminals.................................................................10
Faults, Warnings and Alarms ......................................10
Error Status .............................................................10
VLT 6000 Network Strategies
Strategy One ...........................................................11
Strategy Two........................................................... 11
Strategy Three .........................................................13
Strategy Four...........................................................13
Vista de página 0
1 2 3 4 5 6 ... 26 27

Resumo do Conteúdo

Página 1 - 6000 HVAC

VLT® 6000 HVAC1MG.60.G2.02 - VLT is a registered Danfoss Trademark ContentsIntroductionSafety...

Página 2

VLT® 6000 HVAC10MG.60.G2.02 - VLT is a registered Danfoss TrademarkPID Control Functions (42, 61-65, 68-74)The VLT 6000 has a sophisticated built-i

Página 3

VLT® 6000 HVAC11MG.60.G2.02 - VLT is a registered Danfoss Trademark VLT 6000 Network StrategiesNetwork Inputs to the VLNetwork Inputs to the V

Página 4

VLT® 6000 HVAC12MG.60.G2.02 - VLT is a registered Danfoss TrademarkNOTE:NOTE:NOTE:NOTE:NOTE:Although range listed for point 53 is 32767,that repres

Página 5

VLT® 6000 HVAC13MG.60.G2.02 - VLT is a registered Danfoss TrademarkStrategy ThreeFLN FunctionFLN FunctionFLN FunctionFLN FunctionFLN Function – Mon

Página 6

VLT® 6000 HVAC14MG.60.G2.02 - VLT is a registered Danfoss Trademarkparameter 413. A value of 16383 representsthe maximum feedback signal, as define

Página 7

VLT® 6000 HVAC15MG.60.G2.02 - VLT is a registered Danfoss Trademark6464646464PI I TIMEPI I TIMEPI I TIMEPI I TIMEPI I TIME (parameter 424) - This s

Página 8

VLT® 6000 HVAC16MG.60.G2.02 - VLT is a registered Danfoss TrademarkFigure 3 VLT 6000 Terminator Switch Factory SettingTable 4. Terminator Switch

Página 9

VLT® 6000 HVAC17MG.60.G2.02 - VLT is a registered Danfoss TrademarkElectrical Control TerminalsIn most cases, the VLT 6000 will have electricalcont

Página 10

VLT® 6000 HVAC18MG.60.G2.02 - VLT is a registered Danfoss TrademarkTypical Control Connection ExamplesTTTTTwo Feedback Signals:wo Feedback Signals:

Página 11

VLT® 6000 HVAC19MG.60.G2.02 - VLT is a registered Danfoss TrademarkParameter Description Default Desired setting *500 Protocol FC FLN *501 Addr

Página 12

VLT® 6000 HVAC2MG.60.G2.02 - VLT is a registered Danfoss TrademarkVLT 6000 Special FunctionsSafety Interlock ...

Página 13

VLT® 6000 HVAC20MG.60.G2.02 - VLT is a registered Danfoss TrademarkStartup of FLN ControlThis procedure assumes that the VLT 6000frequency converte

Página 14

VLT® 6000 HVAC21MG.60.G2.02 - VLT is a registered Danfoss TrademarkTTTTTable 7 able 7 able 7 able 7 able 7 Faults, Warnings and Alarms Description

Página 15

VLT® 6000 HVAC22MG.60.G2.02 - VLT is a registered Danfoss TrademarkPoint Mapping TableThe VLT 6000 parameters, along with the internalvariables and

Página 16

VLT® 6000 HVAC23MG.60.G2.02 - VLT is a registered Danfoss Trademark{33} LOCK PANEL Note 5 OPEN -- -- -- -- LOCK OPEN R/W 12-15 LDO {34} SEL HND.

Página 17

VLT® 6000 HVAC24MG.60.G2.02 - VLT is a registered Danfoss Trademark{65} PI GAIN LIM 5 -- 0.1 0 511 -- -- R/W 426 LAO {66} LOWPASS FLTR 0

Página 18

VLT® 6000 HVAC25MG.60.G2.02 - VLT is a registered Danfoss TrademarkPoint Mapping Table Notes:Point numbers that appear in brackets { } may be unbun

Página 19

VLT® 6000 HVAC26MG.60.G2.02 - VLT is a registered Danfoss TrademarkPoint Database DefinitionsTTTTTable 9able 9able 9able 9able 9 Point Database De

Página 20

VLT® 6000 HVAC27MG.60.G2.02 - VLT is a registered Danfoss Trademark53 BUS REF Sends drive an external reference signal in percent.54 SLEEP FREQ.S D

Página 21

VLT® 6000 HVAC3MG.60.G2.02 - VLT is a registered Danfoss TrademarkRotating shafts and electrical equipmentcan be hazardous. Therefore, it is strong

Página 22

VLT® 6000 HVAC4MG.60.G2.02 - VLT is a registered Danfoss TrademarkAbout This ManualThe documentation in this manual providescomprehensive informati

Página 23

VLT® 6000 HVAC5MG.60.G2.02 - VLT is a registered Danfoss Trademark Programming the VLT 6000Parameter Change KeysThe LCP keys are divided into

Página 24

VLT® 6000 HVAC6MG.60.G2.02 - VLT is a registered Danfoss TrademarkThe CANCEL key is used if a change ofthe selected parameter is not to becarried o

Página 25

VLT® 6000 HVAC7MG.60.G2.02 - VLT is a registered Danfoss TrademarkTable 1 Quick Menu Items DescriptionDuring programming of parameters, mo-tor ma

Página 26

VLT® 6000 HVAC8MG.60.G2.02 - VLT is a registered Danfoss Trademark7. Press “-” key until ‘6’ counts down to ‘0’ andsetting for Ramp Up Time reads ‘

Página 27

VLT® 6000 HVAC9MG.60.G2.02 - VLT is a registered Danfoss TrademarkCurrent Monitoring and Limits (19, 30)The maximum current that the drive provides